    EV7-S Terminal – Malfunctions

    Problem Cause Remedy
    9999999 The scale is overloaded Reduce the weight to a value below the maximum scale capacity.
    The terminal remains off Poor battery autonomy Carry out a “battery charging”
    operation. Change the battery set if the fault persists.
    Poor battery autonomy Perform a “first charging” operation Change the battery set if the
    fault persists.
    POW.ER The standard adapter was wrongly connected for the first charging operation. Change the standard adapter for the one supplied with the battery set.

    EV7-S Terminal – Error Messages

    Problem Cause Remedy
    -01-
    Converter failure
    Scale connector disconnected or broken / Conversion board failure Switch the terminal off and make sure that the connector is correctly connected. If necessary, disconnect it, re-connect it and then power the terminal again. / Contact our team.
    -02-
    EEPROM error
    Voltage drop during an incorrect operation Reset the instrument. If the error persists, contact our team for possible replacement of the CPU board.
    -04-
    RAM checksum error
    -05-
    EPROM checksum error
    CPU board fault Reset the instrument; If the error persists, contact our team for possible replacement of the CPU
    board.
    PC.ERR Communication error with the PC Check the cable that connects to the PC.

    Make sure that the PC is on and that the program has been installed correctly.

    Make sure that the port that
    communicates with the PC
    has been set up:

    access the Setup Menu by following pathway Person/MPP/COPC and select COM.1 (see par. 8.5.6 on page 1-101).

    NO ENAB During the installation phase, the weighing operation was enabled via serial link. The weighing operation cannot therefore be requested by pressing Do not press key

    To request the weighing operation by pressing key , access the Setup Menu by following the pathway Person/MPP/RICH and select TASTO (see par. 8.5.6 on page 1-101).

     

    If you have a EV7-S Terminal, and are having issues, contact our team for servicing and support.

    Contact us

      Upload Your CV Below. We Accept The Following File Types: PNG, JPG/JPEG, PDF & DOC/DOCX. Max File Size: 32MB

      Frequently Asked Questions

      What is a Weighbridge?

      A Weighbridge (US truck scale) is a large, low-profile scale used to weigh both road and off-road vehicles (rigid and articulated lorries, dumper trucks, vans etc) and their contents. The load carried by the vehicle is calculated by weighing the vehicle both empty and loaded. The main weighbridge deck structure can be constructed from steel, pre-stressed concrete or steel-concrete composite.

      What is a Pit-Mounted Weighbridge?

      Installed inside a pit, these weighbridges sit flush with the road surface. As they don’t require ramps, they take up less road surface compared to surface mount installations. Suitable for sites with restricted access.

      What is a Surface-Mounted Weighbridge?

      Installed above ground, these weighbridges incorporate steel or concrete ramps to allow vehicles to drive on and off. One advantage is that the ramps slow down vehicle entry speed. Less foundation works are required when compared with pit mount installations. Surface designs are suitable for temporary/portable installations when used with steel ramps.

      Google Rating
      5.0
      Based on 26 reviews
      js_loader